Two-dimensional gel electrophoresis

Two-dimensional gel electrophoresis

Two-dimensional gel electrophoresis, abbreviated as 2-DE or 2-D electrophoresis, is a form of gel electrophoresis commonly used to analyze proteins. Mixtures of proteins are separated by two properties in two dimensions on 2D gels.

Basis for separation

2-D electrophoresis begins with 1-D electrophoresis but then separates the molecules by a second property in a direction 90 degrees from the first. In 1-D electrophoresis, proteins (or other molecules) are separated in one dimension, so that all the proteins/molecules will lie along a lane but be separated from each other by a property (e.g. isoelectric point). The result is that the molecules are spread out across a 2-D gel. Because it is unlikely that two molecules will be similar in two distinct properties, molecules are more effectively separated in 2-D electrophoresis than in 1-D electrophoresis.

The two dimensions that proteins are separated into using this technique can be isoelectric point, protein complex mass in the native state, and protein mass.

To separate the proteins by isoelectric point is called isoelectric focusing (IEF). Thereby, a gradient of pH is applied to a gel and an electric potential is applied across the gel, making one end more positive than the other. At all pHs other than their isoelectric point, proteins will be charged. If they are positively charged, they will be pulled towards the more negative end of the gel and if they are negatively charged they will be pulled to the more positive end of the gel. The proteins applied in the first dimension will move along the gel and will accumulate at their isoelectric point; that is, the point at which the overall charge on the protein is 0 (a neutral charge).

For the analysis of the functioning of proteins in a cell, the knowledge of their cooperation is essential. Most often proteins act together in complexes to be fully functional. The analysis of this sub organelle organisation of the cell requires techniques conserving the native state of the protein complexes. In native polyacrylamide gel electrophoresis (native PAGE), proteins remain in their native state and are separated in the electric field following their mass and the mass of their complexes respectively. To obtain a separation by size and not by net charge, as in IEF, an additional charge is transferred to the proteins by the use of coomassie or lithium dodecyl sulfate (LDS). After completion of the first dimension the complexes are destroyed by applying the denaturing SDS-PAGE in the second dimension, where the proteins of which the complexes are composed of are separated by their mass.

Before separating the proteins by mass, they are treated with sodium dodecyl sulfate (SDS) along with other reagents (SDS-PAGE in 1-D). This denatures the proteins (that is, it unfolds them into long, straight molecules) and binds a number of SDS molecules roughly proportional to the protein’s length. Because a protein’s length (when unfolded) is roughly proportional to its mass, this is equivalent to saying that it attaches a number of SDS molecules roughly proportional to the protein’s mass. Since the SDS molecules are negatively charged, the result of this is that all of the proteins will have approximately the same mass-to-charge ratio as each other. In addition, proteins will not migrate when they have no charge (a result of the isoelectric focusing step) therefore the coating of the protein in SDS (negatively charged) allows migration of the proteins in the second dimension (NB SDS is not compatible for use in the first dimension as it is charged and a nonionic or zwitterionic detergent needs to be used). In the second dimension, an electric potential is again applied, but at a 90 degree angle from the first field. The proteins will be attracted to the more positive side of the gel proportionally to their mass-to-charge ratio. As previously explained, this ratio will be nearly the same for all proteins. The proteins’ progress will be slowed by frictional forces. The gel therefore acts like a molecular sieve when the current is applied, separating the proteins on the basis of their molecular weight with larger proteins being retained higher in the gel and smaller proteins being able to pass through the sieve and reach lower regions of the gel.

The result of this is a gel with proteins spread out on its surface. These proteins can then be detected by a variety of means, but the most commonly used stains are silver and coomassie staining. In this case, a silver colloid is applied to the gel. The silver binds to cysteine groups within the protein. The silver is darkened by exposure to ultra-violet light. The darkness of the silver can be related to the amount of silver and therefore the amount of protein at a given location on the gel. This measurement can only give approximate amounts, but is adequate for most purposes.

Molecules other than proteins can be separated by 2D electrophoresis. In supercoiling assays, coiled DNA is separated in the first dimension and denatured by a DNA intercalator (such as ethidium bromide or the less carcinogenic chloroquine) in the second. This is comparable to the combination of native PAGE /SDS-PAGE in protein separation.

In summary 2D provides resolution according to two traits, whereof one is most often molecular charge. The investigated molecule needs not be protein.

2D Gel Analysis Software

Warping: Images of two 2D electrophoresis gels, overlaid with Delta2D. First image is colored in orange, second one colored in blue. Due to running differences, corresponding spots do not overlap.

Warping: Images of two 2D electrophoresis gels after warping. First image is colored in orange, second one colored in blue. Corresponding spots overlap after warping. Common spots are colored black, orange spots are only present (or much stronger) on the first image, blue spots are only present (or much stronger) on the second image.

In quantitative proteomics, these tools primarily analyze bio-markers by quantifying individual proteins, and showing the separation between one or more protein “spots” on a scanned image of a 2-DE gel. Additionally, these tools match spots between gels of similar samples to show, for example, proteomic differences between early and advanced stages of an illness. Software packages include Delta2D, ImageMaster, Melanie, PDQuest, Progenesis and REDFIN – among others. While this technology is widely utilized, the intelligence has not been perfected. For example, while PDQuest and Progenesis tend to agree on the quantification and analysis of well-defined well-separated protein spots, they deliver different results and analysis tendencies with less-defined less-separated spots.[1]

Challenges for automatic software-based analysis include:

  • incompletely separated (overlapping) spots (less-defined and/or separated)
  • weak spots / noise (e.g., “ghost spots”)
  • running differences between gels (e.g., protein migrates to different positions on different gels)
  • unmatched/undetected spots, leading to missing values[2]
  • mismatched spots
  • errors in quantification (several distinct spots may be erroneously detected as a single spot by the software and/or parts of a spot may be excluded from quantification)
  • differences in software algorithms and therefore analysis tendencies

Generated picking lists can be used for the automated in-gel digestion of protein spots, and subsequent identification of the proteins by mass spectrometry.

For an overview of the current approach for software analysis of 2DE gel images see [3] or [4].

External links

  • A 2-D electrophoresis tutorial on the web site of the Parasitology Group at Aberystwyth University
  • JVirGel Create virtual 2-D Gels from sequence data.
  • fixingproteomics.org Protocols for preparing samples and running 2-D Gels.nnn
  • Gel IQ A freely downloadable software tool for assessing the quality of 2D gel image analysis data.

References

  1. Arora PS, Yamagiwa H, Srivastava A, Bolander ME, Sarkar G (2005). “Comparative evaluation of two two-dimensional gel electrophoresis image analysis software applications using synovial fluids from patients with joint disease”. J Orthop Sci 10 (2): 160–6. doi:10.1007/s00776-004-0878-0. PMID 15815863. http://www.springerlink.com/openurl.asp?genre=article&doi=10.1007/s00776-004-0878-0.
  2. Pedreschi R, Hertog ML, Carpentier SC, et al (April 2008). “Treatment of missing values for multivariate statistical analysis of gel-based proteomics data”. Proteomics 8 (7): 1371–83. doi:10.1002/pmic.200700975. PMID 18383008.
  3. Berth M, Moser FM, Kolbe M, Bernhardt J (October 2007). “The state of the art in the analysis of two-dimensional gel electrophoresis images”. Appl. Microbiol. Biotechnol. 76 (6): 1223–43. doi:10.1007/s00253-007-1128-0. PMID 17713763.
  4. Bandow JE, Baker JD, Berth M, et al (August 2008). “Improved image analysis workflow for 2-D gels enables large-scale 2-D gel-based proteomics studies–COPD biomarker discovery study”. Proteomics 8 (15): 3030–41. doi:10.1002/pmic.200701184. PMID 18618493. http://www3.interscience.wiley.com/journal/120749796.

Posted in Electrophoresis, ProteomicsComments (0)

A gentle introduction to western blotting

A gentle introduction to western blotting

Introduction

The western blot (alternatively, protein immunoblot) is a semi-quantitative analytical technique used to detect specific proteins in a given sample of tissue homogenate or extract, often used to determine the effect of an experimental treatment on protein expression in cells or tissue. The approach uses gel electrophoresis to separate native or denatured proteins by the length of the polypeptide (denaturing conditions) or by the 3-D structure of the protein (native/ non-denaturing conditions). The proteins are then transferred to a membrane (typically nitrocellulose or PVDF), where they are probed (detected) using antibodies specific to the target protein.[2][3]

There are now many reagent companies that specialize in providing antibodies (both monoclonal and polyclonal antibodies) against tens of thousands of different proteins[4]. Commercial antibodies can be expensive, although the unbound antibody can be reused between experiments. This method is used in the fields of molecular biology, biochemistry, immunogenetics and other molecular biology disciplines.

Other related techniques include using antibodies to detect proteins in tissues and cells by immunostaining and enzyme-linked immunosorbent assay (ELISA).

The method originated from the laboratory of George Stark at Stanford. The name western blot was given to the technique by W. Neal Burnette[5] and is a play on the name Southern blot, a technique for DNA detection developed earlier by Edwin Southern. Detection of RNA is termed northern blotting and the detection of post-translational modification of protein is termed eastern blotting.

Western blotting is used in a wide variety of medical diagnostic applications such,

  • The confirmatory HIV test employs a Western blot to detect anti-HIV antibody in a human serum sample. Proteins from known HIV-infected cells are separated and blotted on a membrane as above. Then, the serum to be tested is applied in the primary antibody incubation step; free antibody is washed away, and a secondary anti-human antibody linked to an enzyme signal is added. The stained bands then indicate the proteins to which the patient’s serum contains antibody.
  • A Western blot is also used as the definitive test for Bovine spongiform encephalopathy (BSE, commonly referred to as ‘mad cow disease’).
  • Some forms of Lyme disease testing employ Western blotting.
  • Western blot can also be used as a confirmatory test for Hepatitis B infection.
  • In veterinary medicine, Western blot is sometimes used to confirm FIV+ status in cats.

Steps involved in a western blot

Tissue preparation


Samples may be taken from whole tissue or from cell culture. In most cases, solid tissues are first broken down mechanically using a blender (for larger sample volumes), using a homogenizer (smaller volumes), or by sonication. Cells may also be broken open by one of the above mechanical methods. However, it should be noted that bacteria, virus or environmental samples can be the source of protein and thus Western blotting is not restricted to cellular studies only.

Assorted detergents, salts, and buffers may be employed to encourage lysis of cells and to solubilize proteins. Protease and phosphatase inhibitors are often added to prevent the digestion of the sample by its own enzymes. Tissue preparation is often done at cold temperatures to avoid protein denaturing.

A combination of biochemical and mechanical techniques – including various types of filtration and centrifugation – can be used to separate different cell compartments and organelles..

Gel electrophoresis

The proteins of the sample are separated using gel electrophoresis. Separation of proteins may be by isoelectric point (pI), molecular weight, electric charge, or a combination of these factors. The nature of the separation depends on the treatment of the sample and the nature of the gel. This is a very useful way to determine a protein.

By far the most common type of gel electrophoresis employs polyacrylamide gels and buffers loaded with sodium dodecyl sulfate (SDS). SDS-PAGE (SDS polyacrylamide gel electrophoresis) maintains polypeptides in a denatured state once they have been treated with strong reducing agents to remove secondary and tertiary structure (e.g. disulfide bonds [S-S] to sulfhydryl groups [SH and SH]) and thus allows separation of proteins by their molecular weight. Sampled proteins become covered in the negatively charged SDS and move to the positively charged electrode through the acrylamide mesh of the gel. Smaller proteins migrate faster through this mesh and the proteins are thus separated according to size (usually measured in kilodaltons, kDa). The concentration of acrylamide determines the resolution of the gel – the greater the acrylamide concentration the better the resolution of lower molecular weight proteins. The lower the acrylamide concentration the better the resolution of higher molecular weight proteins. Proteins travel only in one dimension along the gel for most blots.

Samples are loaded into wells in the gel. One lane is usually reserved for a marker or ladder, a commercially available mixture of proteins having defined molecular weights, typically stained so as to form visible, coloured bands. When voltage is applied along the gel, proteins migrate into it at different speeds. These different rates of advancement (different electrophoretic mobilities) separate into bands within each lane.

It is also possible to use a two-dimensional (2-D) gel which spreads the proteins from a single sample out in two dimensions. Proteins are separated according to isoelectric point (pH at which they have neutral net charge) in the first dimension, and according to their molecular weight in the second dimension.

Transfer

In order to make the proteins accessible to antibody detection, they are moved from within the gel onto a membrane made of nitrocellulose or polyvinylidene difluoride (PVDF). The membrane is placed on top of the gel, and a stack of filter papers placed on top of that. The entire stack is placed in a buffer solution which moves up the paper by capillary action, bringing the proteins with it. Another method for transferring the proteins is called electroblotting and uses an electric current to pull proteins from the gel into the PVDF or nitrocellulose membrane. The proteins move from within the gel onto the membrane while maintaining the organization they had within the gel. As a result of this “blotting” process, the proteins are exposed on a thin surface layer for detection (see below). Both varieties of membrane are chosen for their non-specific protein binding properties (i.e. binds all proteins equally well). Protein binding is based upon hydrophobic interactions, as well as charged interactions between the membrane and protein. Nitrocellulose membranes are cheaper than PVDF, but are far more fragile and do not stand up well to repeated probings.

The uniformity and overall effectiveness of transfer of protein from the gel to the membrane can be checked by staining the membrane with Coomassie or Ponceau S dyes. Ponceau S is the more common of the two, due to Ponceau S’s higher sensitivity and its water solubility makes it easier to subsequently destain and probe the membrane as described below.[6] Coomassie dyes are generally incompatible with western b

Blocking

Since the membrane has been chosen for its ability to bind protein, and both antibodies and the target are proteins, steps must be taken to prevent interactions between the membrane and the antibody used for detection of the target protein (since the antibody is a protein itself). Blocking of non-specific binding is achieved by placing the membrane in a dilute solution of protein – typically Bovine serum albumin (BSA) or non-fat dry milk (both are inexpensive), with a minute percentage of detergent such as Tween 20. The protein in the dilute solution attaches to the membrane in all places where the target proteins have not attached. Thus, when the antibody is added, there is no room on the membrane for it to attach other than on the binding sites of the specific target protein. This reduces “noise” in the final product of the Western blot, leading to clearer results, and eliminates false positives.

Detection

During the detection process the membrane is “probed” for the protein of interest with a modified antibody which is linked to a reporter enzyme, which when exposed to an appropriate substrate drives a colourimetric reaction and produces a colour. For a variety of reasons, this traditionally takes place in a two-step process, although there are now one-step detection methods available for certain applications.

Two step

Primary antibody

Antibodies are generated when a host species or immune cell culture is exposed to the protein of interest (or a part thereof). Normally, this is part of the immune response, whereas here they are harvested and used as sensitive and specific detection tools that bind the protein directly.

After blocking, a dilute solution of primary antibody (generally between 0.5 and 5 micrograms/mL) is incubated with the membrane under gentle agitation. Typically, the solution is composed of buffered saline solution with a small percentage of detergent, and sometimes with powdered milk or BSA. The antibody solution and the membrane can be sealed and incubated together for anywhere from 30 minutes to overnight. It can also be incubated at different temperatures, with warmer temperatures being associated with more binding, both specific (to the target protein, the “signal”) and non-specific (“noise”).

Secondary antibody

After rinsing the membrane to remove unbound primary antibody, the membrane is exposed to another antibody, directed at a species-specific portion of the primary antibody. This is known as a secondary antibody, and due to its targeting properties, tends to be referred to as “anti-mouse,” “anti-goat,” etc. Antibodies come from animal sources (or animal sourced hybridoma cultures); an anti-mouse secondary will bind to almost any mouse-sourced primary antibody. This allows some cost savings by allowing an entire lab to share a single source of mass-produced antibody, and provides far more consistent results. The secondary antibody is usually linked to biotin or to a reporter enzyme such as alkaline phosphatase or horseradish peroxidase. This means that several secondary antibodies will bind to one primary antibody and enhance the signal.

Most commonly, a horseradish peroxidase-linked secondary is used to cleave a chemiluminescent agent, and the reaction product produces luminescence in proportion to the amount of protein. A sensitive sheet of photographic film is placed against the membrane, and exposure to the light from the reaction creates an image of the antibodies bound to the blot. A cheaper but less sensitive approach utilizes a 4-chloronaphthol stain with 1% hydrogen peroxide; reaction of peroxide radicals with 4-chloronaphthol produces a dark brown stain that can be photographed without using specialized photographic film.

As with the ELISPOT and ELISA procedures, the enzyme can be provided with a substrate molecule that will be converted by the enzyme to a colored reaction product that will be visible on the membrane (see the figure below with blue bands).

Another method of secondary antibody detection utilizes a near-infrared (NIR) fluorophore-linked antibody. Light produced from the excitation of a fluorescent dye is static, making fluorescent detection a more precise and accurate measure of the difference in signal produced by labeled antibodies bound to proteins on a Western blot. Proteins can be accurately quantified because the signal generated by the different amounts of proteins on the membranes is measured in a static state, as compared to chemiluminescence, in which light is measured in a dynamic state. [7]

A third alternative is to use a radioactive label rather than an enzyme coupled to the secondary antibody, such as labeling an antibody-binding protein like Staphylococcus Protein A with a radioactive isotope of iodine. Since other methods are safer, quicker and cheaper this method is now rarely used.

One step

Historically, the probing process was performed in two steps because of the relative ease of producing primary and secondary antibodies in separate processes. This gives researchers and corporations huge advantages in terms of flexibility, and adds an amplification step to the detection process. Given the advent of high-throughput protein analysis and lower limits of detection, however, there has been interest in developing one-step probing systems that would allow the process to occur faster and with less consumables. This requires a probe antibody which both recognizes the protein of interest and contains a detectable label, probes which are often available for known protein tags. The primary probe is incubated with the membrane in a manner similar to that for the primary antibody in a two-step process, and then is ready for direct detection after a series of wash steps.

Western blot using radioactive detection system

Detection Methods

After the unbound probes are washed away, the Western blot is ready for detection of the probes that are labeled and bound to the protein of interest. In practical terms, not all Westerns reveal protein only at one band in a membrane. Size approximations are taken by comparing the stained bands to that of the marker or ladder loaded during electrophoresis. The process is repeated for a structural protein, such as actin or tubulin, also refered to as a loading control (follow link for examples of appropriate loading controls) that are not expected to change between samples. The amount of target protein is indexed to the structural protein to control between groups. This practice ensures correction for the amount of total protein on the membrane in case of errors or incomplete transfers.

Colorimetric detection

The colorimetric detection method depends on incubation of the Western blot with a substrate that reacts with the reporter enzyme (such as peroxidase) that is bound to the secondary antibody. This converts the soluble dye into an insoluble form of a different color that precipitates next to the enzyme and thereby stains the membrane. Development of the blot is then stopped by washing away the soluble dye. Protein levels are evaluated through densitometry (how intense the stain is) or spectrophotometry.

Chemiluminescent detection


Chemiluminescent detection methods depend on incubation of the Western blot with a substrate that will luminesce when exposed to the reporter on the secondary antibody. The light is then detected by photographic film, and more recently by CCD cameras which capture a digital image of the western blot. The image is analysed by densitometry, which evaluates the relative amount of protein staining and quantifies the results in terms of optical density. Newer software allows further data analysis such as molecular weight analysis if appropriate standards are used.

Radioactive detection

Radioactive labels do not require enzyme substrates, but rather allow the placement of medical X-ray film directly against the western blot which develops as it is exposed to the label and creates dark regions which correspond to the protein bands of interest (see image to the right). The importance of radioactive detections methods is declining[citation needed], because it is very expensive, health and safety risks are high and ECL provides a useful alternative.

Fluorescent detection

The fluorescently labeled probe is excited by light and the emission of the excitation is then detected by a photosensor such as CCD camera equipped with appropriate emission filters which captures a digital image of the western blot and allows further data analysis such as molecular weight analysis and a quantitative western blot analysis. Fluorescence is considered to be among the most sensitive detection methods for blotting analysis.

Secondary probing

One major difference between nitrocellulose and PVDF membranes relates to the ability of each to support “stripping” antibodies off and reusing the membrane for subsequent antibody probes. While there are well-established protocols available for stripping nitrocellulose membranes, the sturdier PVDF allows for easier stripping, and for more reuse before background noise limits experiments. Another difference is that, unlike nitrocellulose, PVDF must be soaked in 95% ethanol, isopropanol or methanol before use. PVDF membranes also tend to be thicker and more resistant to damage during use.

2-D gel electrophoresis

2-dimensional SDS-PAGE uses the principles and techniques outlined above, and we refer you to the expanded article for examples of the application of 2-D SDS PAGE. 2-D SDS-PAGE, as the name suggests, involves the migration of polypeptides in 2 dimensions. For example, in the first dimension polypeptides are separated according to isoelectric point, while in the second dimension polypeptides are separated according to their molecular weight. The isoelectric point of a given protein is determined by the relative number of positively (e.g. lysine and arginine) and negatively (e.g. glutamate and aspartate) charged amino acids, with negatively charged amino acids contributing to a high isoelectric point and positively charged amino acids contributing to a low isoelectric point. Samples could also be separated first under nonreducing conditions using SDS-PAGE and under reducing conditions in the second dimension, which breaks apart disulfide bonds that hold subunits together. SDS-PAGE might also be coupled with urea-PAGE for a 2-dimensional gel.

In principle, this method allows for the separation of all cellular proteins on a single large gel. A major advantage of this method is that it often distinguishes between different isoforms of a particular protein – e.g. a protein that has been phosphorylated (by addition of a negatively charged group). Proteins that have been separated can be cut out of the gel and then analysed by mass spectrometry, which identifies the protein.

Medical diagnostic applications

References

  1. Hempelmann E, Schirmer RH, Fritsch G, Hundt E, Gröschel-Stewart U (1987). “Studies on glutathione reductase and methemoglobin from human erythrocytes parasitized with Plasmodium falciparum.”. Mol Biochem Parasitol. 23 (1): 19–24. doi:10.1016/0166-6851(87)90182-4. PMID 3553936.
  2. Towbin H, Staehelin T, Gordon J. (1979). “Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.”. Proc Natl Acad Sci U S A. 76 (9): 4350–4354. doi:10.1073/pnas.76.9.4350. PMID 388439.
  3. Renart J, Reiser J, Stark GR (1979). “Transfer of proteins from gels to diazobenzyloxymethyl-paper and detection with antisera: a method for studying antibody specificity and antigen structure.”. Proc Natl Acad Sci U S A. 76 (7): 3116–3120. doi:10.1073/pnas.76.7.3116. PMID 91164.
  4. “Western blot antibody”. exactantigen.com. http://www.exactantigen.com/review/western-blot-antibody.html. Retrieved 2009-01-29.
  5. W. Neil Burnette (April 1981). “‘Western blotting’: electrophoretic transfer of proteins from sodium dodecyl sulfate — polyacrylamide gels to unmodified nitrocellulose and radiographic detection with antibody and radioiodinated protein A“. Analytical Biochemistry (United States: Academic Press) 112 (2): 195–203. doi:10.1016/0003-2697(81)90281-5. ISSN 0003-2697. PMID 6266278. . Retrieved 2008-04-03.
  6. Source.

Posted in Proteomics, Western BlottingComments (0)

Loading Controls

Loading Controls

Loading controls are commonly used in gel electrophoresis techniques, such as western blotting, to verify that the gel lanes have been evenly loaded with sample material, and they are typically used to standardize the results from these studies. Since the proteins in loading controls are abundantly expressed, they also allow investigators to determine if there is an even transfer across the entire gel. A loading control is absolutely required when western blots are prepared for publication.

Beta Actin
Origin: Whole Cell / cytoplasmic
Molecular weight (kD): 43
Beta actin is one of six isoforms of actin. Actin is a globular, roughly 42-kDa protein found in all eukaryotic cells (except for nematode sperm) where it may be present at concentrations of over 100 ?M. It is also one of the most highly-conserved proteins, differing by no more than 20% in species as diverse as algae and humans. It is the monomeric subunit of microfilaments, one of the three major components of the cytoskeleton, and of thin filaments, which are part of the contractile apparatus in muscle cells. Thus, actin participates in many important cellular functions, including muscle contraction, cell motility, cell division and cytokinesis, vesicle and organelle movement, cell signaling, and the establishment and maintenance of cell junctions and cell shape. This loading control is not suitable for skeletal muscle samples. Changes in cell-growth conditions and interactions with extracellular matrix components may alter actin protein synthesis (Farmer et al, 1983).

Glyceraldehyde 3-phosphate dehydrogenase (GAPDH)
Origin: Whole Cell / cytoplasmic
Molecular weight (kD):30-40
Because the GAPDH gene is often stably and constitutively expressed at high levels in most tissues and cells, it is considered a housekeeping gene. For this reason, GAPDH is commonly used by biological researchers as a loading control for western blot and as a control for RT-PCR. However, many researchers report different regulation of GAPDH under specific conditions. Consequently, the use of GAPDH as loading control has to be carefully evaluated.

Tubulin
Whole Cell / cytoplasmic
Molecular weight (kD):55
Tubulin is one of several members of a small family of globular proteins. The most common members of the tubulin family are ?-tubulin and ?-tubulin, the proteins that make up microtubules. Each has a molecular weight of approximately 55 kiloDaltons. Microtubules are assembled from dimers of ?- and ?-tubulin. These subunits are slightly acidic with an isoelectric point between 5.2 and 5.8. Tubulin expression may vary according to resistance to antimicrobial and antimitotic drugs (Sangrajrang S. et al, 1998, Prasad V et al, 2000)

VDCA1/Porin
Mitochondrial
Molecular weight (kD): 31
Porins are beta barrel proteins that cross a cellular membrane and act as a pore through which molecules can diffuse. Unlike other membrane transport proteins, porins are large enough to allow passive diffusion – i.e., they act as channels that are specific to different types of molecules. They are present in the outer membrane of Gram-negative bacteria, the mitochondria, and the chloroplast.

Cytochrome C Oxidase (COXIV )
Mitochondrial
Molecular weight (kD):16
Cytochrome C Oxidase (COXIV) is located in the inner mitochondrial membrane and serves as the terminal enzyme complex of the mitochondrial electron transport chain. COXIV collects electrons that are transferred from reduced cytochrome C and donates them to molecular oxygen, resulting in reduction to water. COXIV is expressed at a consistently high level and thus makes a good mitochondrial loading control; however, many proteins run at the same size.

Lamin B1
Origin: Nuclear envelope
Molecular weight (kD): 66
The nuclear lamina consists of a two-dimensional matrix of proteins located next to the inner nuclear membrane. The lamin family of proteins make up the matrix and are highly conserved in evolution. During mitosis, the lamina matrix is reversibly disassembled as the lamin proteins are phosphorylated. Lamin proteins are thought to be involved in nuclear stability, chromatin structure and gene expression. Vertebrate lamins consist of two types, A and B. This gene encodes one of the two B type proteins, B1. This protein is not suitable for samples where the nuclear envelope has been removed.

TATA binding protein TBP
Origin: Nuclear
Molecular weight (kD):38
The TATA binding protein (TBP) is a transcription factor that binds specifically to a DNA sequence called the TATA box. This DNA sequence is found about 25-30 base pairs upstream of the transcription start site in some eukaryotic gene promoters. TBP, along with a variety of TBP-associated factors, make up the TFIID, a general transcription factor that in turn makes up part of the RNA polymerase II preinitiation complex. As one of the few proteins in the preinitation complex that binds DNA in a sequence-specific manner, it helps position RNA polymerase II over the transcription start site of the gene. However, it is estimated that only 10-20% of human promoters have TATA boxes. Therefore, TBP is probably not the only protein involved in positioning RNA polymerase II. This protein is not suitable for samples where the nuclear envelope has been removed.

Posted in Western BlottingComments (0)